<ErrorMessage>
ALE2: Measured height = %imm (%i.%i\"), Entered = %imm (%i.%i\") - RESUME to use measured
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>ThermoFlex</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
If size is always coming out short - check that plates are cut squarely and table
plate sensor is being covered for the entire length of the plate.
Re-calibrating the stl parameter may be required if the plates are OK.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
If measured plate size is still acceptable select resume otherwise cancel.
</text></DescriptionText>
</OperatorAction>
<Cause>
The measured plate size does not agree with the submitted plate size within tolerance.
</Cause>